n707sm
Joined: 07 Jun 2007 Posts: 6
|
Posted: Sun Dec 09, 2007 9:53 am Post subject: Z-19/RB Eng Bat (2-10) switch unused in On postion? |
|
|
I'm confused about the wiring for the "Eng Bat (2-10)" switch depicted in
the Z-19/RB architecture diagram. Please help me to understand.
Here is what I read this switch wiring to be:
Pin 1: Connected to Pin 5
Pin 2: Feed to energize Engine Battery contactor
Pin 3: Open
Pin 4: 12 volts input
Pin 5: Connected to Pin 1
Pin 6: Ground
I can see how the switch will provide 12 volts to the Engine Battery
Contactor in the up "Auto" position, but I don't understand how this switch
(in this wiring configuration) will provide 12 volts to the Engine Battery
contactor in the center "On" position.
To test, I have connected Pin 1 to Pin 5. Then with a continuity test
function on my Auto Ranging Multimeter, I test for continuity between Pin 4 and Pin 2 with the switch in the center On position, and also in the up Auto position. I only receive continuity in the up Auto position.
What am I missing?
Thanks in advance,
Michael
| - The Matronics AeroElectric-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?AeroElectric-List |
|
|
|