PostPosted: Fri Dec 12, 2008 8:03 am    Post subject: Grounding Of Fuel Senders Reply with quote

I am installing VDO fuel senders in the metal fuel tanks of my all-metal kit aircraft. These senders do not have a ground lug, and the sender, by design, is not isolated from the fuel tank because the mounting screws are inserted into a metal mounting ring which is in metal-to-metal contact with the inside of the fuel tank. The construction manual calls for grounding the sender to the airframe using a wire from the airframe to a ring terminal under one of the mounting screws. My concern with this approach is that I might inadvertently introduce a “ground loop” into the system by grounding in this fashion. I would prefer to isolate the sender from the airframe and run a return wire to the universal ground buss on the firewall, but because of the design of the sender this would be difficult to do. Has anyone else dealt with installation of these senders, and if so, can you offer me any advice?
Thanks,
Dave Van Lanen [quote][b]


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
View user's profile Send private message
recapen(at)earthlink.net
Guest





PostPosted: Fri Dec 12, 2008 8:46 am    Post subject: Grounding Of Fuel Senders Reply with quote

I added these wires to my RV6A (metal tanks) to ground the senders to the main spar which has a bonding strap to the field of tabs ground bus.

Works fine so far - no adverse effects - will be flying first flight in a couple of weeks - just got my airworthiness cert.

Ralph Capen
RV6A N822AR 0 hrs
--


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
ftyoder(at)yoderbuilt.com
Guest





PostPosted: Fri Dec 12, 2008 10:18 am    Post subject: Grounding Of Fuel Senders Reply with quote

Congratulations on the FAA Cert....... Enjoy that first flight!!!

Tim
---


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
nuckolls.bob(at)aeroelect
Guest





PostPosted: Fri Dec 12, 2008 7:06 pm    Post subject: Grounding Of Fuel Senders Reply with quote

At 10:02 AM 12/12/2008, you wrote:

Quote:
I am installing VDO fuel senders in the metal fuel tanks of my all-metal kit aircraft. These senders do not have a ground lug, and the sender, by design, is not isolated from the fuel tank because the mounting screws are inserted into a metal mounting ring which is in metal-to-metal contact with the inside of the fuel tank. The construction manual calls for grounding the sender to the airframe using a wire from the airframe to a ring terminal under one of the mounting screws. My concern with this approach is that I might inadvertently introduce a “ground loop” into the system by grounding in this fashion. I would prefer to isolate the sender from the airframe and run a return wire to the universal ground buss on the firewall, but because of the design of the sender this would be difficult to do. Has anyone else dealt with installation of these senders, and if so, can you offer me any advice?

Metal tanks in a metal airplane will provide sufficient
ground for these senders to work as advertised. Adding
the wire as directed in the instructions will not hurt
anything either. Go ahead and install the requested wire


Bob . . .

----------------------------------------)
( . . . a long habit of not thinking )
( a thing wrong, gives it a superficial )
( appearance of being right . . . )
(       )
(   -Thomas Paine 1776- )
----------------------------------------

[quote][b]


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
dvanlanen



Joined: 25 Jul 2006
Posts: 122
Location: Madison, WI

PostPosted: Sat Dec 13, 2008 8:44 am    Post subject: Grounding Of Fuel Senders Reply with quote

Bob,
Can you explain why I don’t need to worry about a ground loop in this situation, (reference the explanation of ground loops on p. 5-6 of the AeroElectric manual)?
Thanks,
Dave



Date: Dec 12, 2008

From: "Robert L. Nuckolls, III" <nuckolls.bob(at)aeroelectric.com>

Subject: Re: Grounding Of Fuel Senders

At 10:02 AM 12/12/2008, you wrote:
Quote:
I am installing VDO fuel senders in the metal fuel tanks of my
all-metal kit aircraft. These senders do not have a ground lug, and
the sender, by design, is not isolated ………
Metal tanks in a metal airplane will provide sufficient

ground for these senders to work as advertised. Adding
the wire as directed in the instructions will not hurt
anything either. Go ahead and install the requested wire

Bob . . . [quote][b]


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
View user's profile Send private message
nuckolls.bob(at)aeroelect
Guest





PostPosted: Sat Dec 13, 2008 12:52 pm    Post subject: Grounding Of Fuel Senders Reply with quote

At 10:38 AM 12/13/2008, you wrote:

Quote:
Bob,

Can you explain why I don’t need to worry about a ground loop in this situation, (reference the explanation of ground loops on p. 5-6 of the AeroElectric manual)?

Thanks,

Dave

Because the loop is small. The tank grounds to the
airframe through mounting straps and brackets and
with a resistance that is a tiny fraction that of
any piece of wire you might install. Yeah, technically
there's a "loop" but so tiny both in architecture and
in terms of antagonistic currents as to be insignificant.


Bob . . .

----------------------------------------)
( . . . a long habit of not thinking )
( a thing wrong, gives it a superficial )
( appearance of being right . . . )
( )
( -Thomas Paine 1776- )
----------------------------------------

[quote][b]


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Matronics Email Lists Forum Index -> AeroElectric-List All times are GMT - 8 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum


Powered by phpBB © 2001, 2005 phpBB Group