Gilles.Thesee(at)ac-greno
Guest





PostPosted: Wed Jul 08, 2009 8:18 am    Post subject: Grounding question Reply with quote

Hi Bob and all,

A buddy asked for help in adapting the wiring of his factory built Rotax 912 S aircraft.
He wishes something more similar to fig Z16

His battery, contactor, regulator and capacitor are under the seats, whereas the ground bus is on the firewall.
The factory originally grounded the regulator and battery contactor direct at the minus post of the battery.
Is it advisable to retain this configuration, or would it be better to ground those at the ground bus on the firewall, and retain only one fat ground wire running from the fwl to the minus pole of the battery.

Thanks in advance for your help,

Best regards,
Gilles
http://contrails.free.fr


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
nuckolls.bob(at)aeroelect
Guest





PostPosted: Fri Jul 10, 2009 11:51 am    Post subject: Grounding question Reply with quote

At 11:17 AM 7/8/2009, you wrote:
Quote:
--> AeroElectric-List message posted by: Gilles.Thesee(at)ac-grenoble.fr

Hi Bob and all,

A buddy asked for help in adapting the wiring of his factory built Rotax 912 S aircraft.
He wishes something more similar to fig Z16

His battery, contactor, regulator and capacitor are under the seats, whereas the ground bus is on the firewall.
The factory originally grounded the regulator and battery contactor direct at the minus post of the battery.
Is it advisable to retain this configuration, or would it be better to ground those at the ground bus on the firewall, and retain only one fat ground wire running from the fwl to the minus pole of the battery.

Thanks in advance for your help,

You will note that none of the Z-figures attaches
more than single, fat-wire to a battery terminal. I know
some manufacturers of electro-whizzies are fond
of asking builders to "hook my product right to the
battery terminals".

In the world of TC aircraft, we're sensitive to the
effects of wrench-monkies who routinely replace certain
articles over the lifetime of the airplane. Batteries
certainly get replaced about as often as tires. It's
not considered good practice to inject more variability
than necessary into the reliable opening/closing of
a fastener. Hence, batteries never get more than one
wire on their terminals. In some cases, we even eliminated
human-induced variability by designing batteries with
connectors on them!

[img]cid:7.1.0.9.0.20090710143816.01da7dd8(at)aeroelectric.com.0[/img]
The short answer is, I recommend you stay with the architecture
described in Z-16.


Bob . . .

---------------------------------------
( . . . a long habit of not thinking )
( a thing wrong, gives it a superficial )
( appearance of being right . . . )
( )
( -Thomas Paine 1776- )
---------------------------------------


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List



188635a.jpg
 Description:
 Filesize:  5.1 KB
 Viewed:  1320 Time(s)

188635a.jpg


Back to top
Gilles.Thesee(at)ac-greno
Guest





PostPosted: Sat Jul 18, 2009 1:52 pm    Post subject: Grounding question Reply with quote

Robert L. Nuckolls, III a écrit :
Quote:

The short answer is, I recommend you stay with the architecture
described in Z-16.


Bob,

Thank you for your response.
Sorry for answering late, but I've been with no Internet connection for
several weeks.

Thanks again,
Best regards,
--
Gilles
http://contrails.free.fr


- The Matronics AeroElectric-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?AeroElectric-List
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Matronics Email Lists Forum Index -> AeroElectric-List All times are GMT - 8 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum


Powered by phpBB © 2001, 2005 phpBB Group