Fred Klein
Joined: 26 Mar 2012 Posts: 503
|
Posted: Thu Oct 10, 2013 6:33 pm Post subject: Withdraw Question on pwr. dist. diag. Z-19 |
|
|
Bob...question withdrawn, as I more carefully review the diagram...Fred
Bob,
On Z-19, I note that the dual batteries are connected in parallel via a brass strap and via grounds which both go to the PNL; one feeds a "Main Battery Bus"; the other feeds the "Engine Battery Bus"; the ECU and fuel pump are fed from both busses via "Engine Primary" and "Engine Secondary" switches and diode bridges.
What I don't understand is why, since the dual batteries are connected, are 2 busses necessary?...Why not just one bus being fed off either of the 2 batteries?...is there a battery failure mode with dual batteries which would preclude drawing current from the good battery thru the failed battery?
Fred
| - The Matronics AeroElectric-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more: