Ernie



Joined: 11 Jan 2006
Posts: 513

PostPosted: Thu Mar 12, 2015 2:16 pm    Post subject: Main Air Tank Reply with quote

Here are pics of the tank I fashioned for my plane.

Specs:
Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.
Weight 10 lbs
Length 21"
Diameter 7"
Hydro Tested to 7500 PSI.

Fittings:
Stainless Steel SCBA to NPT Adapter
NPT to AN #4 Male Adapter.
This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.
[img]cid:ii_14c100d2fd57eeb6[/img][img]cid:ii_14c100d55d2f94fa[/img]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List



IMG_0095_2.jpg
 Description:
 Filesize:  667.3 KB
 Viewed:  3746 Time(s)

IMG_0095_2.jpg



IMG_0096_2.jpg
 Description:
 Filesize:  669.83 KB
 Viewed:  3746 Time(s)

IMG_0096_2.jpg


Back to top
View user's profile Send private message
hkgibby(at)yahoo.com
Guest





PostPosted: Thu Mar 12, 2015 3:11 pm    Post subject: Main Air Tank Reply with quote

Ernie-
Jax Fluid Technologies 904-642-2093 is a nearby source for Swagelok tubing/ferrules/valves that might help you finish things off. You should do a Red Star article when all done with your setup...looks good. Keep us posted.

Hoot

Sent from my iPhone

Quote:
On Mar 12, 2015, at 6:15 PM, Ernest Martinez <erniel29(at)gmail.com> wrote:

Here are pics of the tank I fashioned for my plane.

Specs:

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.
Weight 10 lbs
Length 21"
Diameter 7"
Hydro Tested to 7500 PSI.

Fittings:
Stainless Steel SCBA to NPT Adapter
NPT to AN #4 Male Adapter.

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

<IMG_0095_2.jpg><IMG_0096_2.jpg>






- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
samira.h(at)shaw.ca
Guest





PostPosted: Thu Mar 12, 2015 4:08 pm    Post subject: Main Air Tank Reply with quote

Hi Ernie,

Sir - you are a genius, thank you so much for your posting.

Please don't get discouraged by some others, your solution
is plain great.

Thank you again.

Blue Skies and Happy Landings.

cheers

Elmar


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
Dawg



Joined: 19 May 2013
Posts: 355

PostPosted: Thu Mar 12, 2015 6:43 pm    Post subject: Main Air Tank Reply with quote

good job Ernie.
On Mar 13, 2015, at 7:15 AM, Ernest Martinez <erniel29(at)gmail.com> wrote:

Quote:
Here are pics of the tank I fashioned for my plane.

Specs:

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.
Weight 10 lbs
Length 21"
Diameter 7"
Hydro Tested to 7500 PSI.

Fittings:
Stainless Steel SCBA to NPT Adapter
NPT to AN #4 Male Adapter.

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

<IMG_0095_2.jpg><IMG_0096_2.jpg>






- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List

_________________
Dawg
Back to top
View user's profile Send private message
cd001633(at)mindspring.co
Guest





PostPosted: Thu Mar 12, 2015 8:59 pm    Post subject: Main Air Tank Reply with quote

Ernie,

Would a Drain port be needed here as in the original tank for draining moisture/water?

Sam



From: owner-yak-list-server(at)matronics.com [mailto:owner-yak-list-server(at)matronics.com] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank

Here are pics of the tank I fashioned for my plane.


Specs:



Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.



Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.



This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.



[img]cid:image002.jpg(at)01D05D28.4CDECFD0[/img][img]cid:image004.jpg(at)01D05D28.4CDECFD0[/img]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List



image002.jpg
 Description:
 Filesize:  31.93 KB
 Viewed:  3730 Time(s)

image002.jpg



image004.jpg
 Description:
 Filesize:  29.42 KB
 Viewed:  3730 Time(s)

image004.jpg


Back to top
Dawg



Joined: 19 May 2013
Posts: 355

PostPosted: Fri Mar 13, 2015 2:17 am    Post subject: Main Air Tank Reply with quote

Air dryer filter as on airlines for paint gun? Cheap and easy before bottle.

Sent from my iPad

On Mar 13, 2015, at 13:58, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:
v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} <![endif]--> <![endif]--> <![endif]-->
Ernie,

Would a Drain port be needed here as in the original tank for draining moisture/water?

Sam



From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank

Here are pics of the tank I fashioned for my plane.


Specs:



Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.



Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.



This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.



<image002.jpg><image004.jpg>









[quote][b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List

_________________
Dawg
Back to top
View user's profile Send private message
Dawg



Joined: 19 May 2013
Posts: 355

PostPosted: Fri Mar 13, 2015 2:21 am    Post subject: Main Air Tank Reply with quote

Don't just have one machined. Have a couple just in case. (In case I need one!)

Sent from my iPad

Quote:
On Mar 13, 2015, at 07:15, Ernest Martinez <erniel29(at)gmail.com> wrote:

Here are pics of the tank I fashioned for my plane.

Specs:

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.
Weight 10 lbs
Length 21"
Diameter 7"
Hydro Tested to 7500 PSI.

Fittings:
Stainless Steel SCBA to NPT Adapter
NPT to AN #4 Male Adapter.

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

<IMG_0095_2.jpg><IMG_0096_2.jpg>






- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List

_________________
Dawg
Back to top
View user's profile Send private message
Ernie



Joined: 11 Jan 2006
Posts: 513

PostPosted: Fri Mar 13, 2015 3:44 am    Post subject: Main Air Tank Reply with quote

Sam,

Good question. Unfortunately High Pressure tanks have to be seamless so a drain port is not a possibility. This is why it's important to keep your air dryer serviced. But since it's aluminum rust isn't an issue. Would have to make it part of the annual service routine to remove and dump.
Ernie
On Fri, Mar 13, 2015 at 12:58 AM, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:

Ernie,
 
Would a Drain port be needed here as in the original tank for draining moisture/water?
 
Sam
 
 
 
From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank
 
Here are pics of the tank I fashioned for my plane.
 

Specs:

 

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.

 

Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.

 

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

 

[img]cid:image002.jpg(at)01D05D28.4CDECFD0[/img][img]cid:image004.jpg(at)01D05D28.4CDECFD0[/img]

 

 

 

 



- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List



image002.jpg
 Description:
 Filesize:  31.93 KB
 Viewed:  3727 Time(s)

image002.jpg



image004.jpg
 Description:
 Filesize:  29.42 KB
 Viewed:  3727 Time(s)

image004.jpg


Back to top
View user's profile Send private message
Ernie



Joined: 11 Jan 2006
Posts: 513

PostPosted: Fri Mar 13, 2015 4:23 am    Post subject: Main Air Tank Reply with quote

Bill,

I didn't machine it, you can buy the adapter on Ebay for $35.
Ernie
On Fri, Mar 13, 2015 at 6:20 AM, Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)> wrote:
[quote]--> Yak-List message posted by: Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)>

Don't just have one machined. Have a couple just in case. (In case I need one!)

Sent from my iPad

> On Mar 13, 2015, at 07:15, Ernest Martinez <erniel29(at)gmail.com (erniel29(at)gmail.com)> wrote:
>
> Here are pics of the tank I fashioned for my plane.
>
> Specs:
>
> Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.
> Weight 10 lbs
> Length 21"
> Diameter 7"
> Hydro Tested to 7500 PSI.
>
> Fittings:
> Stainless Steel SCBA to NPT Adapter
> NPT to AN #4 Male Adapter.
>
> This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.
>
> <IMG_0095_2.jpg><IMG_0096_2.jpg>
>
>
>
>


===========
List" target="_blank">http://www.matronics.com/Navigator?Yak-List
===========
FORUMS -
_blank">http://forums.matronics.com
===========
b Site -
          -Matt Dralle, List Admin.
target="_blank">http://www.matronics.com/contribution
===========





[b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
View user's profile Send private message
kelmonroe(at)comcast.net
Guest





PostPosted: Fri Mar 13, 2015 4:28 am    Post subject: Main Air Tank Reply with quote

Has anyone had work done at Eagle Works Aviation/Dan Payne in Hixon
Tennessee?
Thanks Kelley Monroe

--


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
Viperdoc



Joined: 19 Apr 2014
Posts: 484
Location: 08A

PostPosted: Fri Mar 13, 2015 5:16 am    Post subject: Main Air Tank Reply with quote

What is the lone pressure from the compressor to the tank?
Doc

Sent from my iPad

On Mar 13, 2015, at 5:16 AM, Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)> wrote:
[quote]Air dryer filter as on airlines for paint gun? Cheap and easy before bottle.

Sent from my iPad

On Mar 13, 2015, at 13:58, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:
v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} <![endif]--> <![endif]--> <![endif]-->
Ernie,

Would a Drain port be needed here as in the original tank for draining moisture/water?

Sam



From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank

Here are pics of the tank I fashioned for my plane.


Specs:



Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.



Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.



This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.



<image002.jpg><image004.jpg>











D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D


[b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List

_________________
Viperdoc
Back to top
View user's profile Send private message
Ernie



Joined: 11 Jan 2006
Posts: 513

PostPosted: Fri Mar 13, 2015 5:24 am    Post subject: Main Air Tank Reply with quote

Not quite sure I understand your question. Are you referring to the main air tank or the emergency tank scenario I illustrated?

Nothing changes WRT to the main air tank mod. Its just a simple replacement. The air pressure in the tank would be whatever you have your pressure relief valve set to, generally 50 bar or about 750 PSI.
With the emergency tank, there is no input to the emergency bottle. It is standalone with just output to the emergency circuit. The pressure in the bottle is 4500 PSI, regulated down to 800 PSI.
Ernie
On Fri, Mar 13, 2015 at 9:15 AM, Roger Kemp <f16viperdoc(at)me.com (f16viperdoc(at)me.com)> wrote:
[quote]What is the lone pressure from the compressor to the tank?
Doc

Sent from my iPad

On Mar 13, 2015, at 5:16 AM, Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)> wrote:
Quote:
Air dryer filter as on airlines for paint gun? Cheap and easy before bottle.

Sent from my iPad

On Mar 13, 2015, at 13:58, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:

Ernie,
 
Would a Drain port be needed here as in the original tank for draining moisture/water?
 
Sam
 
 
 
From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank
 
Here are pics of the tank I fashioned for my plane.
 

Specs:

 

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.

 

Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.

 

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

 

<image002.jpg><image004.jpg>

 

 

 

 



D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D




et="_blank">http://www.matronics.com/Navigator?Yak-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution


[b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
View user's profile Send private message
mark.bitterlich(at)navy.m
Guest





PostPosted: Fri Mar 13, 2015 10:28 am    Post subject: Main Air Tank Reply with quote

Another difference between the YAK-50 and YAK-52 original design.

On the 52, the emergency bottle is only filled via the aircrafts external fill port. Main bottle is filled by either the external fill port, or the engine compressor.

On the YAK-50, both bottles are filled by the engine compressor or the external fill port.

Not sure why they were designed differently, but that said the 52 emergency bottle is a one shot kind of thing, once it empty, it's empty. On the 50, you can close it, wait for it to pump up in-flight and try it again.

Mark
--


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
rocknpilot(at)hotmail.com
Guest





PostPosted: Fri Mar 13, 2015 10:48 am    Post subject: Main Air Tank Reply with quote

Mark,

Does the 50 also have shuttle valves?

Rico Jaeger
915 S. 11th Ave.
Wausau, WI. 54401
715.529.7426
//
1966 Cessna 150F ^/---//-X
N8558G //Hangar #35 / AUW
//
1992 Yakovlev Yak 52^/---//-X
N21YK //
Hangar #21 / AUW



[quote] From: mark.bitterlich(at)navy.mil
To: yak-list(at)matronics.com
Subject: RE: Main Air Tank
Date: Fri, 13 Mar 2015 18:27:59 +0000

--> Yak-List message posted by: "Bitterlich, Mark G CIV NAVAIR, WD" <mark.bitterlich(at)navy.mil>

Another difference between the YAK-50 and YAK-52 original design.

On the 52, the emergency bottle is only filled via the aircrafts external fill port. Main bottle is filled by either the external fill port, or the engine compressor.

On the YAK-50, both bottles are filled by the engine compressor or the external fill port.

Not sure why they were designed differently, but that said the 52 emergency bottle is a one shot kind of thing, once it empty, it's empty. On the 50, you can close it, wait for it to pump up in-flight and try it again.

Mark


--


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
mark.bitterlich(at)navy.m
Guest





PostPosted: Fri Mar 13, 2015 6:00 pm    Post subject: Main Air Tank Reply with quote

Yes, it does.

Mark

________________________________
From: owner-yak-list-server(at)matronics.com [owner-yak-list-server(at)matronics.com] on behalf of Rico Jaeger [rocknpilot(at)hotmail.com]
Sent: Friday, March 13, 2015 2:48 PM
To: yak-list(at)matronics.com
Subject: RE: Main Air Tank

Mark,

Does the 50 also have shuttle valves?

Rico Jaeger
915 S. 11th Ave.
Wausau, WI. 54401
715.529.7426
//
1966 Cessna 150F ^/---//-X
N8558G //
Hangar #35 / AUW
//
1992 Yakovlev Yak 52 ^/---//-X
N21YK //
Hangar #21 / AUW


[quote] From: mark.bitterlich(at)navy.mil
To: yak-list(at)matronics.com
Subject: RE: Main Air Tank
Date: Fri, 13 Mar 2015 18:27:59 +0000



Another difference between the YAK-50 and YAK-52 original design.

On the 52, the emergency bottle is only filled via the aircrafts external fill port. Main bottle is filled by either the external fill port, or the engine compressor.

On the YAK-50, both bottles are filled by the engine compressor or the external fill port.

Not sure why they were designed differently, but that said the 52 emergency bottle is a one shot kind of thing, once it empty, it's empty. On the 50, you can close it, wait for it to pump up in-flight and try it again.

Mark
--


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
wlannon(at)shaw.ca
Guest





PostPosted: Sat Mar 14, 2015 7:23 pm    Post subject: Main Air Tank Reply with quote

Ernie;

“Since it’s aluminum rust isn’t an issue”. That may be the case but only if it is pure aluminum which is protected from corrosion by it’s own oxide layer. If it is an alloy that protection is seriously degraded depending on the alloy composition and strength.

Pure aluminum has a strength something like cheddar cheese. However if the entire strength of the tank is derived from the carbon fibre wrapping then pure aluminum would be suitable.
Something to consider.

Walt

From: Ernest Martinez (erniel29(at)gmail.com)
Sent: Friday, March 13, 2015 4:36 AM
To: yak-list (yak-list(at)matronics.com)
Subject: Re: Main Air Tank


Sam,
Good question. Unfortunately High Pressure tanks have to be seamless so a drain port is not a possibility. This is why it's important to keep your air dryer serviced. But since it's aluminum rust isn't an issue. Would have to make it part of the annual service routine to remove and dump.

Ernie


On Fri, Mar 13, 2015 at 12:58 AM, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:

Ernie,

Would a Drain port be needed here as in the original tank for draining moisture/water?

Sam



From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank

Here are pics of the tank I fashioned for my plane.


Specs:



Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.



Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.



This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.



[img]cid:3E1306D8CD464D6AB7151734EBAA121F(at)WalterHP[/img][img]cid:BECBC68057F24B84ABA24AB021F4B313(at)WalterHP[/img]











- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List



image002.jpg
 Description:
 Filesize:  31.93 KB
 Viewed:  3686 Time(s)

image002.jpg



image004.jpg
 Description:
 Filesize:  29.42 KB
 Viewed:  3686 Time(s)

image004.jpg


Back to top
Viperdoc



Joined: 19 Apr 2014
Posts: 484
Location: 08A

PostPosted: Sat Mar 14, 2015 9:16 pm    Post subject: Main Air Tank Reply with quote

Line pressure from the compressor before entering the pop- off valve. Miss typed the word line. Came over as lone.
Sorry poor proof reading,
Doc

Sent from my iPad

On Mar 13, 2015, at 8:23 AM, Ernest Martinez <erniel29(at)gmail.com (erniel29(at)gmail.com)> wrote:
[quote]Not quite sure I understand your question. Are you referring to the main air tank or the emergency tank scenario I illustrated?

Nothing changes WRT to the main air tank mod. Its just a simple replacement. The air pressure in the tank would be whatever you have your pressure relief valve set to, generally 50 bar or about 750 PSI.
With the emergency tank, there is no input to the emergency bottle. It is standalone with just output to the emergency circuit. The pressure in the bottle is 4500 PSI, regulated down to 800 PSI.
Ernie
On Fri, Mar 13, 2015 at 9:15 AM, Roger Kemp <f16viperdoc(at)me.com (f16viperdoc(at)me.com)> wrote:
Quote:
What is the lone pressure from the compressor to the tank?
Doc

Sent from my iPad

On Mar 13, 2015, at 5:16 AM, Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)> wrote:
Quote:
Air dryer filter as on airlines for paint gun? Cheap and easy before bottle.

Sent from my iPad

On Mar 13, 2015, at 13:58, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:

Ernie,

Would a Drain port be needed here as in the original tank for draining moisture/water?

Sam



From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank

Here are pics of the tank I fashioned for my plane.


Specs:



Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.



Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.



This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.



<image002.jpg><image004.jpg>











D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D




et="_blank">http://www.matronics.com/Navigator?Yak-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution




D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D


[b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List

_________________
Viperdoc
Back to top
View user's profile Send private message
Ernie



Joined: 11 Jan 2006
Posts: 513

PostPosted: Sun Mar 15, 2015 6:18 am    Post subject: Main Air Tank Reply with quote

Yep you're correct, if it's not the right alloy, it could be a problem. Fortunately these things are strictly regulated. The aluminum tanks by themselves are rated for 2260 PSI, the Carbon Fiber brought them up to 4500 PSI. Again, at the pressures I'm going to run it at, its not an issue at all. Also remember aluminum scuba tanks are made of the same stuff and live in salt water all their lives. At the end of the day it's all about diligent maintenance.

The reason I'm doing this because I'm terrified of my current 40 yr old steel welded tank, that I have no reliable history on, and can't get hydrotested locally. Yes I know there is some place I can ship it to, but I have several issues with that. I'd rather be able to do it locally and have it back the next day. And I like the fact that it's tested to known parameters (7500 PSI), and a guy is willing to put his name on it and certify it.

But since it doesn't fit where the original tank goes I've given my self a good reason to mount it where it will be VERY easy to remove Smile The stock tanks lives under my smoke system and Battery box, shelf and I'm going to have to remove everything to get the bottle out.
Ernie

On Sun, Mar 15, 2015 at 1:14 AM, Roger Kemp <f16viperdoc(at)me.com (f16viperdoc(at)me.com)> wrote:
[quote]Line pressure from the compressor before entering the pop- off valve. Miss typed the word line. Came over as lone. 
Sorry poor proof reading,
Doc

Sent from my iPad

On Mar 13, 2015, at 8:23 AM, Ernest Martinez <erniel29(at)gmail.com (erniel29(at)gmail.com)> wrote:
Quote:
Not quite sure I understand your question. Are you referring to the main air tank or the emergency tank scenario I illustrated?

Nothing changes WRT to the main air tank mod. Its just a simple replacement. The air pressure in the tank would be whatever you have your pressure relief valve set to, generally 50 bar or about 750 PSI.
With the emergency tank, there is no input to the emergency bottle. It is standalone with just output to the emergency circuit. The pressure in the bottle is 4500 PSI, regulated down to 800 PSI.
Ernie
On Fri, Mar 13, 2015 at 9:15 AM, Roger Kemp <f16viperdoc(at)me.com (f16viperdoc(at)me.com)> wrote:
Quote:
What is the lone pressure from the compressor to the tank?
Doc

Sent from my iPad

On Mar 13, 2015, at 5:16 AM, Bill Geipel <l129bs(at)gmail.com (l129bs(at)gmail.com)> wrote:
Quote:
Air dryer filter as on airlines for paint gun? Cheap and easy before bottle.

Sent from my iPad

On Mar 13, 2015, at 13:58, Sam Sax <cd001633(at)mindspring.com (cd001633(at)mindspring.com)> wrote:
Quote:

Ernie,
 
Would a Drain port be needed here as in the original tank for draining moisture/water?
 
Sam
 
 
 
From: owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com) [mailto:owner-yak-list-server(at)matronics.com (owner-yak-list-server(at)matronics.com)] On Behalf Of Ernest Martinez
Sent: Thursday, March 12, 2015 6:15 PM
To: yak-list
Subject: Main Air Tank
 
Here are pics of the tank I fashioned for my plane.
 

Specs:

 

Drager 4500 PSI 60 min Carbon Fiber Wrapped Aluminum Tank.

Weight 10 lbs

Length 21"

Diameter 7"

Hydro Tested to 7500 PSI.

 

Fittings:

Stainless Steel SCBA to NPT Adapter

NPT to AN #4 Male Adapter.

 

This should fit in the same bracket where the stock tanks lives. All thats left is to create an aluminum tube pigtail with an AN B-Nut on one end and the Chinese Nut on the other.

 

<image002.jpg><image004.jpg>

 

 

 

 



D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D




et="_blank">http://www.matronics.com/Navigator?Yak-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution




D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ist"">http://www.matronics.com/Navigator?Yak-List
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
//forums.matronics.com
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
ot;">http://www.matronics.com/contribution
D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D




et="_blank">http://www.matronics.com/Navigator?Yak-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution


[b]


- The Matronics Yak-List Email Forum -
 

Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:

http://www.matronics.com/Navigator?Yak-List
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic   Reply to topic    Matronics Email Lists Forum Index -> Yak-List All times are GMT - 8 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum


Powered by phpBB © 2001, 2005 phpBB Group