		art(at)zemon.name Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 6:29 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
	
  
	 
	
	
		
	 
	
		|  Description: | 
		
			
		 | 
	 
	
		|  Filesize: | 
		 1.1 MB | 
	 
	
		|  Viewed: | 
		 17811 Time(s) | 
	 
	
		
  
 
  | 
	 
	 
	 
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		cluros(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 7:09 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				How do you know the connection was tight?
 
 On Wed, Jul 25, 2018, 10:38 Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
 
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
   | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		art(at)zemon.name Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 7:11 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Correction. The plane has a shunt, not a current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
 On Wed, Jul 25, 2018, 10:08 AM Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
 
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
   | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		echristley(at)att.net Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 7:37 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Looks like a lead post.  Lead has a fairly low melting point.  Maybe the wire was heated from the other end enough to soften the battery post material.  Once soft, the connection was degraded, leading to a high resistance connection. Leading to ... goo running down the side of the battery?
  
     On Wednesday, July 25, 2018 10:31 AM, Art Zemon <art(at)zemon.name> wrote:
 
   
 
  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		argoldman(at)aol.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 7:41 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Lessee, a loose connection (no matter where it is from or to) is potentially a high resistance connection. With the tremendous power draw of the starter motor it is likely that that was the source of the heat and meltage.
  
 
  Rich
  
 
  
  In a message dated 7/25/2018 10:11:48 AM Central Standard Time, art(at)zemon.name writes: 
 
    	  | Quote: | 	 		    Correction. The plane has a shunt, not a current limiter.
 
      -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
  
  
   On Wed, Jul 25, 2018, 10:08 AM Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
   	  | Quote: | 	 		   Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo. 
 
  I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
      -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
  
  
   | 	   
  
   | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		art(at)zemon.name Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 8:00 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Because it still is, after the battery terminal melted and the bolt fell off. The lock nut is now soldered in it's compressed state between the bolt head and the washer.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
 On Jul 25, 2018 10:30 AM, "Sebastien" <cluros(at)gmail.com (cluros(at)gmail.com)> wrote: 	  | Quote: | 	 		  How do you know the connection was tight?
 
 On Wed, Jul 25, 2018, 10:38 Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
 
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
   | 	  
  
  | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		ceengland7(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 8:06 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				On Wed, Jul 25, 2018 at 9:28 AM, Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
   | 	  
 If I  had to speculate, I'd be looking at the battery type, in addition to the question of whether there really was a clean gas tight connection on the posts. If you look up the specs on that battery, I'll bet you'll find it was intended for service in UPS, powered wheel chair, etc. You can get away with using 'universal' batteries for starting; I've used the SLA universals as starting batteries for a couple of decades. But the terminals are typically a lot smaller than a true starting battery. Even if the terminals were clean/tight, I wonder if a drastically extended cranking session could drive heat up enough to melt the terminals, which are likely sized for, let's say, 20 amps continuous, instead of 200+.
 Charlie
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		nuckolls.bob(at)aeroelect Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 8:25 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				At 09:28 AM 7/25/2018, you wrote:
   	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
  I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter. | 	  
    Was the current limiter in series with starter
    current . . .? If the 'loose' terminal was not
    visibly damaged due to electrically induced
    heating/arcing, then it did not participate
    in this failure.
 
    How did the battery wire terminal look after the 'meltdown'?
 
    Lead has right at 10x the d.c. resistance of copper.
    Not sure what comparative gradients for reduction
    in compression strength vs. temperature would be
    but you can bet that lead is MUCH steeper than copper.
 
    This sorta sets up a weak-link for the low resistance,
    high current batteries. An extended cranking scenario
    will absolutely warm up these terminals. Joint integrity
    falls with temperature rise and the trajectory to destruction
    steepens exponentially.
 
    Some suppliers of SVLA products will include a lead
    battery bolt kit that includes a Bellville washer
    to be used in the joint makeup that provides (1) an
    indication as to when design compression in the joint
    has been reached and (2) improve retention of joint
    quality for small rises in temperature.
 
  [img]cid:.0[/img]
 
    Pretty sure this is why Odyssey and similar products
    use a lot of brass in their terminal posts
 
  [img]cid:.1[/img]
 
  [img]cid:.1[/img]
 
  
  
    Bob . . .
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
	
  
	 
	
	
		
	 
	
		|  Description: | 
		
			
		 | 
	 
	
		|  Filesize: | 
		 15.39 KB | 
	 
	
		|  Viewed: | 
		 17813 Time(s) | 
	 
	
		
  
 
  | 
	 
	 
	 
	 
	
	
		
	 
	
		|  Description: | 
		
			
		 | 
	 
	
		|  Filesize: | 
		 30.28 KB | 
	 
	
		|  Viewed: | 
		 17813 Time(s) | 
	 
	
		
  
 
  | 
	 
	 
	 
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		BARRY CHECK 6
 
 
  Joined: 15 Mar 2011 Posts: 738
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 8:56 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Art:
 
 The current limit circuit has nothing to do with it.
 The cable should be going from the battery to the starter relay to the starter.
 There are hundreds of amps being sucked out of the battery.
 Nothing should be limiting the current flow.
 The crank, cranking the engine probably did so WAY TOO LONG!
 Many starters stipulate 10 seconds.  Well, that is too long!  It should be more like 5 seconds.
 The only thing indicating the positive terminal was maybe tight is - It did not melt.
 It does not matter which terminal is loose, positive or negative, resistance is resistance.  And you now have proof of what a poor connection can do.
 Also you do not know if the positive terminal was a CLEAN connection or how tight.  One ohm of resistance under a terminal increases current drawing a 12 VDC circuit by 12 Amps.
 If the plane’s amp gauge reads starting amps, there might be an indication of higher draw than normal.  A good indication to stop cranking.
 Barry 
 
 On Wednesday, July 25, 2018, Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the current limiter got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the current limiter.
 
     -- Art Z.
 
 Sent from my phone. Please excuse brevity and bizarre typos.
   | 	  
 -- 
 Barry
 "Chop'd Liver"
 If you wash your hands before you go to the bathroom you may have the makings of a Crew Chief.
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		nuckolls.bob(at)aeroelect Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 9:59 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				If I  had to speculate, I'd be looking at the battery type, in addition
  to the question of whether there really was a clean gas tight
  connection on the posts. If you look up the specs on that
  battery, I'll bet you'll find it was intended for service in
  UPS, powered wheel chair, etc. You can get away with using
  'universal' batteries for starting; I've used the SLA universals
  as starting batteries for a couple of decades. But the terminals
  are typically a lot smaller than a true starting battery. Even
  if the terminals were clean/tight, I wonder if a drastically
  extended cranking session could drive heat up enough to melt the
  terminals, which are likely sized for, let's say, 20 amps continuous,
  instead of 200+.
 
     Excellent put Charlie . . .
 
     I'm recalling the first SVLA batteries
     B&C offered . . . yeah, they would dump
     700A in a load test but also featured
     the lead molded terminal tabs. It was important
     to educate the buyers about their relative
     fragility . . . that's where the soft-n-floppy,
     welding cable battery jumpers originated . . .
     which remains a good thing to do even with
     the more robust terminals.
 
  
  
    Bob . . .
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		ceengland7(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 10:04 am    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				I think we need to review Ohm's Law and       power formulas for DC circuits.
        http://www.sengpielaudio.com/calculator-ohm.htm
        
        Using P for power, V for volts, R for resistance, and I for       current, pick a formula, and plug in value of 12V (or maybe 10 V,       with the starter load). Then plug in a value for the starter's       resistance. Pick virtually any value you want, but you can get a       fairly realistic one by picking an arbitrary current of 200 amps,       and using V/I=R: 12V/200A=0.06 ohms. 
        
        Now that you have starter resistance, let's use V/R=I: 12/0.06 0       Amps.
        
        Now, add your 1 ohm of extra resistance to the V/R=I formula:       12/(0.06+1.0)=x
        Which reduces to: 12V/1.06R=x
        
        Solve for x, and tell us how adding 1 ohm of series resistance       increases the current.  
        
        Charlie
        
        
        
        On 7/25/2018 11:55 AM, FLYaDIVE wrote:
      
       	  | Quote: | 	 		                
        Art:       
        
        The current limit circuit has nothing to do with it.
        The cable should be going from the battery to the starter         relay to the starter.
        There are hundreds of amps being sucked out of the battery.
        Nothing should be limiting the current flow.
        The crank, cranking the engine probably did so WAY TOO LONG!
        Many starters stipulate 10 seconds.  Well, that is too long!          It should be more like 5 seconds.
        The only thing indicating the positive terminal was maybe         tight is - It did not melt.
        It does not matter which terminal is loose, positive or         negative, resistance is resistance.  And you now have proof of         what a poor connection can do.
        Also you do not know if the positive terminal was a CLEAN         connection or how tight.  One ohm of resistance under a terminal         increases current drawing a 12 VDC circuit by 12 Amps.
        If the plane’s amp gauge reads starting amps, there might be         an indication of higher draw than normal.  A good indication to         stop cranking.
        
        
        Barry 
        
        
        
          On Wednesday, July 25, 2018, Art Zemon <art(at)zemon.name (art(at)zemon.name)>         wrote:
           	  | Quote: | 	 		             Question for y'all. This happened at             AirVenture (not my plane, thankfully). The cable from the             battery positive terminal to the current limiter got loose             at the current limiter end. Just loose, it did not come off.             The pilot kept cranking on the starter until he heard a pop.             The negative terminal on the battery has melted. See photo.             
              
              I don't understand why this is the party               that got hot, since this connector was tight. And why               there is no other visible damage to the battery out               anything else, not even the current limiter.
                
                    --                 Art Z.
                  
                  Sent from my phone. Please excuse brevity and bizarre                 typos.
              
            
           | 	         
        
        
        -- 
        Barry
        "Chop'd Liver"
        If you wash your hands before you go to the bathroom you may have       the makings of a Crew Chief.
       | 	       
      	           		Virus-free. www.avast.com 		 	 [url=#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2] [/url]
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		nuckolls.bob(at)aeroelect Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 12:35 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				At 01:04 PM 7/25/2018, you wrote:
   	  | Quote: | 	 		  I think we need to review Ohm's Law and power formulas for DC circuits.
   http://www.sengpielaudio.com/calculator-ohm.htm
 
  Using P for power, V for volts, R for resistance, and I for current, pick a formula, and plug in value of 12V (or maybe 10 V, with the starter load). Then plug in a value for the starter's resistance. Pick virtually any value you want, but you can get a fairly realistic one by picking an arbitrary current of 200 amps, and using V/I=R: 12V/200A=0.06 ohms. | 	  
    It's a bit more complex than that. A figure lifted from
    the 'Connection will help highlight the details . . .
 
  [img]cid:.0[/img]
 
    A battery has an internal resistance component. So does the starter
    motor. As explained in the DC Motors posting on 6/27, we know that the
    motor windings moving through the magnetic field flux generates a
    COUNTER EMF, i.e. a voltage that opposes the applied voltage.
 
    The starter motor's internal resistance sets the STALL current
    which is the same as INRUSH current. That resistance will be MUCH
    lower than the hypothesized 0.06 ohms cited above. Using 12v as the
    'source' voltage for cranking calculations assumes that OTHER than
    motor resistance, there are no additional resistances. The exemplar
    cranking scenario speaks to a number of resistances not the least
    of which is contained within the battery.
 
    These numbers can be better or worse depending on the system
    configuration and condition of the components but suffice it
    to say that NONE of these resistances are ever so small as
    to be ignored.
 
    Inrush current, while short in duration, is several times
    higher than cranking current. Note that ALL resistances cited
    are, as Charlie suggested in his hypothetical, are measured
    in MILLIOHMS. You don't have to add much resistance to seriously
    impact system performance and in all cases, adding or increasing
    any resistance causes current to go DOWN.
 
  
    Bob . . .
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
	
  
	 
	
	
		
	 
	
		|  Description: | 
		
			
		 | 
	 
	
		|  Filesize: | 
		 153.12 KB | 
	 
	
		|  Viewed: | 
		 17809 Time(s) | 
	 
	
		
  
 
  | 
	 
	 
	 
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		ceengland7(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Wed Jul 25, 2018 2:18 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				You have a lot more words at your disposal than I do.   I was just shooting for a simple way to show that adding series resistance can't make current go *up* in a DC circuit.
 
 Charlie
 On Wed, Jul 25, 2018 at 3:34 PM, Robert L. Nuckolls, III <nuckolls.bob(at)aeroelectric.com (nuckolls.bob(at)aeroelectric.com)> wrote:
  	  | Quote: | 	 		    At 01:04 PM 7/25/2018, you wrote:
   	  | Quote: | 	 		  I think we need to review Ohm's Law and power formulas for DC circuits.
   http://www.sengpielaudio.com/calculator-ohm.htm
 
  Using P for power, V for volts, R for resistance, and I for current, pick a formula, and plug in value of 12V (or maybe 10 V, with the starter load). Then plug in a value for the starter's resistance. Pick virtually any value you want, but you can get a fairly realistic one by picking an arbitrary current of 200 amps, and using V/I=R: 12V/200A=0.06 ohms. | 	  
    It's a bit more complex than that. A figure lifted from
    the 'Connection will help highlight the details . . .
 
  [img]cid:.0[/img]
 
    A battery has an internal resistance component. So does the starter
    motor. As explained in the DC Motors posting on 6/27, we know that the
    motor windings moving through the magnetic field flux generates a
    COUNTER EMF, i.e. a voltage that opposes the applied voltage.
 
    The starter motor's internal resistance sets the STALL current
    which is the same as INRUSH current. That resistance will be MUCH
    lower than the hypothesized 0.06 ohms cited above. Using 12v as the
    'source' voltage for cranking calculations assumes that OTHER than
    motor resistance, there are no additional resistances. The exemplar
    cranking scenario speaks to a number of resistances not the least
    of which is contained within the battery.
 
    These numbers can be better or worse depending on the system
    configuration and condition of the components but suffice it
    to say that NONE of these resistances are ever so small as
    to be ignored.
 
    Inrush current, while short in duration, is several times
    higher than cranking current. Note that ALL resistances cited
    are, as Charlie suggested in his hypothetical, are measured
    in MILLIOHMS. You don't have to add much resistance to seriously
    impact system performance and in all cases, adding or increasing
    any resistance causes current to go DOWN.
 
  
    Bob . . .
    | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
	
  
	 
	
	
		
	 
	
		|  Description: | 
		
			
		 | 
	 
	
		|  Filesize: | 
		 153.12 KB | 
	 
	
		|  Viewed: | 
		 17807 Time(s) | 
	 
	
		
  
 
  | 
	 
	 
	 
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		nuckolls.bob(at)aeroelect Guest
 
 
 
 
 
  | 
		 | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		art(at)zemon.name Guest
 
 
 
 
 
  | 
		
			
				 Posted: Sun Jul 29, 2018 1:12 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Folks,
 I am home now, with access to a real keyboard and a real chair   AirVenture was good this year but immediately followed by a hurried trip to New Jersey with no time to even think.
 Based on your emails, I figured out my hypothesis of what happened:
 - The connector between the cable from the battery to the ammeter shunt got loose, increasing the resistance.
 - For unknown reasons, the engine was hard to start and the pilot kept cranking and cranking and cranking.
 - There is no circuit protection in the circuit battery positive terminal -> shunt -> master contactor -> starter contactor -> starter motor -> engine block -> battery negative terminal
 - Lacking circuit protection, the parts most likely to get hot enough to melt were the lead battery terminals. It was a crap shoot which would fail first, positive or negative. Once the negative got hot enough to loosen up, it got hotter in a hurry and melted.
  Several lessons learned.
 - I don't think that pilot will do that again.
 - I learned that too much cranking puts other components at risk, not just the starter motor.
 - The airplane's owner will be checking the other high current connectors.
 - In diagnosing this issue, I spotted another damaged connection (unrelated problem) on the master contactor so the airplane's owner will fix that too.
 - I have the same battery in my airplane and when it needs replacing, I will choose a model that doesn't have lead terminals.
  Thank you for the education!
 
     -- Art Z.
 On Wed, Jul 25, 2018 at 10:08 AM Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
 
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the shunt
  got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the shunt
 .
   | 	  
 -- 
 https://CheerfulCurmudgeon.com/"We do not see the world as it is. We see the world as we are."
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		ceengland7(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Sun Jul 29, 2018 1:46 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Charlie
  On Jul 29, 2018, at 4:39 PM, Charlie England <ceengland7(at)gmail.com (ceengland7(at)gmail.com)> wrote: 	  | Quote: | 	 		     
   
  
     Charlie   
     On Jul 29, 2018, at 4:18 PM, Art Zemon <  art(at)zemon.name (art(at)zemon.name)> wrote:   	  | Quote: | 	 		               Folks,    
          
     
          I am home now, with access to a real keyboard and a real chair   AirVenture was good this year but immediately followed by a hurried trip to New Jersey with no time to even think.    
          
     
          Based on your emails, I figured out my hypothesis of what happened:    
                - The connector between the cable from the battery to the ammeter shunt got loose, increasing the resistance.      
 - For unknown reasons, the engine was hard to start and the pilot kept cranking and cranking and cranking.      
 - There is no circuit protection in the circuit battery positive terminal -> shunt -> master contactor -> starter contactor -> starter motor -> engine block -> battery negative terminal      
 - Lacking circuit protection, the parts most likely to get hot enough to melt were the lead battery terminals. It was a crap shoot which would fail first, positive or negative. Once the negative got hot enough to loosen up, it got hotter in a hurry and melted.     
             Several lessons learned.     
                   - I don't think that pilot will do that again.       
 - I learned that too much cranking puts other components at risk, not just the starter motor.       
 - The airplane's owner will be checking the other high current connectors.       
 - In diagnosing this issue, I spotted another damaged connection (unrelated problem) on the master contactor so the airplane's owner will fix that too.       
 - I have the same battery in my airplane and when it needs replacing, I will choose a model that doesn't have lead terminals.      
               Thank you for the education!      
      
            
      
                -- Art Z.     
     
     
                On Wed, Jul 25, 2018 at 10:08 AM Art Zemon <      art(at)zemon.name (art(at)zemon.name)> wrote:      
      
       	  | Quote: | 	 		               Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the                shunt       
  got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.               
        
                I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the                  shunt        
 .        
        
       
        | 	      
              
     
          Art, two things, likely unrelated. There should never be a shunt anywhere in the path from battery to starter.    
          
     
          The external components' heat didn't do the damage to the battery. Current exceeding the design limits of that particular battery for to long is likely wht caused the damage.    
          
     
          Charlie    
 See my earlier message about the battery type.
    
     | 	   
  | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		ceengland7(at)gmail.com Guest
 
 
 
 
 
  | 
		
			
				 Posted: Sun Jul 29, 2018 1:48 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Charlie
  On Jul 29, 2018, at 4:18 PM, Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote: 	  | Quote: | 	 		   Folks,
 I am home now, with access to a real keyboard and a real chair   AirVenture was good this year but immediately followed by a hurried trip to New Jersey with no time to even think.
 Based on your emails, I figured out my hypothesis of what happened:
 - The connector between the cable from the battery to the ammeter shunt got loose, increasing the resistance.
 - For unknown reasons, the engine was hard to start and the pilot kept cranking and cranking and cranking.
 - There is no circuit protection in the circuit battery positive terminal -> shunt -> master contactor -> starter contactor -> starter motor -> engine block -> battery negative terminal
 - Lacking circuit protection, the parts most likely to get hot enough to melt were the lead battery terminals. It was a crap shoot which would fail first, positive or negative. Once the negative got hot enough to loosen up, it got hotter in a hurry and melted.
  Several lessons learned.
 - I don't think that pilot will do that again.
 - I learned that too much cranking puts other components at risk, not just the starter motor.
 - The airplane's owner will be checking the other high current connectors.
 - In diagnosing this issue, I spotted another damaged connection (unrelated problem) on the master contactor so the airplane's owner will fix that too.
 - I have the same battery in my airplane and when it needs replacing, I will choose a model that doesn't have lead terminals.
  Thank you for the education!
 
     -- Art Z.
 On Wed, Jul 25, 2018 at 10:08 AM Art Zemon <art(at)zemon.name (art(at)zemon.name)> wrote:
 
  	  | Quote: | 	 		  Question for y'all. This happened at AirVenture (not my plane, thankfully). The cable from the battery positive terminal to the shunt
  got loose at the current limiter end. Just loose, it did not come off. The pilot kept cranking on the starter until he heard a pop. The negative terminal on the battery has melted. See photo.
 
 I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the shunt
 .
   | 	  
 Art, two things, likely unrelated. There should never be a shunt anywhere in the path from battery to starter.
 The external components' heat didn't do the damage to the battery. Current exceeding the design limits of that particular battery for to long is likely wht caused the damage.
 Charlie
 
   | 	 
 
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		nuckolls.bob(at)aeroelect Guest
 
 
 
 
 
  | 
		
			
				 Posted: Sun Jul 29, 2018 4:47 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				 	  | Quote: | 	 		     
   I don't understand why this is the party that got hot, since this connector was tight. And why there is no other visible damage to the battery out anything else, not even the 
   shunt 
   . 
 
   
 
   Art, two things, likely unrelated. There should never be a shunt anywhere in the path from battery to starter. 
 
   The external components' heat didn't do the damage to the battery. Current exceeding the design limits of that particular battery for to long is likely wht caused the damage. 
 
   Charlie 
 
   See my earlier message about the battery type. | 	    
 
    Agreed.
 
  
    Bob . . .
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		user9253
 
 
  Joined: 28 Mar 2008 Posts: 1944 Location: Riley TWP Michigan
  | 
		
			
				 Posted: Sun Jul 29, 2018 5:55 pm    Post subject: Re: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				The reason for the melted battery terminal was, as others have said, a high resistance connection.
 Of course the extended cranking time was a factor.  The terminal might have seemed to be tight,
 but there was still high resistance.  Sometimes the bolt is too long and the nut runs out of threads.
 The nut bottoms out and is tight, but the terminal is not tight.  One time I found a loose connection
 caused by someone using a nut and bolt that did not have matching threads.  For instance a 10-24 nut
 on a 10-32 bolt.  Sure, the nut was tight, but the electrical connection was not tight.
   Circuit protection like a fuse or current limiter is not desired in the starter circuit because it would add
 resistance which would slow down the starter motor.  Circuit protection would not have helped anyway
 because the current was not excessive.  In fact, the high resistance connection reduced the current.
 Lead battery posts are not cause for concern if the terminal is clean and tight.
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 _________________ Joe Gores | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		art(at)zemon.name Guest
 
 
 
 
 
  | 
		
			
				 Posted: Sun Jul 29, 2018 6:00 pm    Post subject: Melted battery terminal | 
				     | 
			 
			
				
  | 
			 
			
				Charlie wrote:
  	  | Quote: | 	 		  | Art, two things, likely unrelated. There should never be a shunt anywhere in the path from battery to starter.  | 	  
 
 Charlie,
 You bring up a good point. You just make me realize that the shunt is in the wrong place, measuring current to/from the battery instead of from the alternator. I don't remember which end of the shunt is connected to the starter contactor. I'll check, though that will take awhile since I am home and the plane is elsewhere now.
  	  | Quote: | 	 		  | The external components' heat didn't do the damage to the battery. Current exceeding the design limits of that particular battery for to long is likely wht caused the damage.  | 	  
 
 I do understand that.
 Cheers,
     -- Art Z.
 
 -- 
 https://CheerfulCurmudgeon.com/"We do not see the world as it is. We see the world as we are."
 
  |  | - The Matronics AeroElectric-List Email Forum - |  |   |  Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
 
  http://www.matronics.com/Navigator?AeroElectric-List |  
  |  
 
 
 
  
 | 
			 
		  | 
	 
	
		| Back to top | 
		 | 
	 
	
		  | 
	 
	
		 | 
	 
 
  
	 
	    
	   | 
	
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum You cannot attach files in this forum You can download files in this forum
  | 
   
 
  
Powered by phpBB © 2001, 2005 phpBB Group
  
		 |