Posted: Thu Jul 27, 2006 3:04 am Post subject: Re : RE: Re : wiring |
|
|
----- Message d'origine -----
De: nigel charles <nwcmc(at)tiscali.co.uk>
Objet: RE: Re : wiring
Quote: |
<nwcmc(at)tiscali.co.uk>
>The Rotax regulator needs a definite voltage to continue providing
power. Disconnect it, or have it fail, or run your battery down, and
you're left with very few option to keep your engine running.<
Not true. If you disconnect the battery with the engine running the
generator continues to supply the electrical system until the revs
dropto idle. Even then, restoring the revs above idle results in the
generator picking up the load.
|
Hi Nigel,
We run the regulator that came with our 914 on the bench, and once disconnected, it won't come to life if the battery is down or off line, regardless of the RPM. This lead to a series of scenarii where we could be left with no power.
Of course it is possible that not all Rotax regulators are the same internally, or you found a particular mode we failed to explore in our experiments. I would be interested in more experimental details on your findings. I could publish them in addition to our measurements.
Best regards,
Gilles
http://contrails.free.fr
| - The Matronics Europa-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?Europa-List |
|
|
|
Back to top |
|
 |
nwcmc(at)tiscali.co.uk Guest
|
Posted: Sun Jul 30, 2006 8:12 am Post subject: Re : RE: Re : wiring |
|
|
All I can say is that after having done an external battery start one
day I forgot to reinstate the onboard battery before disconnecting the
external power so hence the comments below.
Nigel Charles
--
| - The Matronics Europa-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?Europa-List |
|
|
|
Back to top |
|
 |
paul.mcallister
Joined: 09 Jan 2006 Posts: 177 Location: Waukesha, WI USA
|
Posted: Sun Jul 30, 2006 10:55 am Post subject: Re : RE: Re : wiring |
|
|
Nigel, Gilles
I have had the same experience as Nigel during systems failure mode check
outs. Once the regulator was excited it continued to run.
I suspect that there might be some variation between regulators that account
for this. Actually (touch wood) my regulator has 470 hours / 2.5 years on
it and so far it is holding up well. I am hoping that a combination of a
modest load and a cool location is going to keep it that way.
Regards, Paul
--