Posted: Thu Jan 20, 2011 6:08 am Post subject: voltage regulators/alternator |
|
|
I thought I was going to mount my alternator this weekend and finish everything up. Again no instruction in the box for the Plane Power alternator, so I looked online and found the installation instructions.
WHere do I purchase the R1224 regulator? I didn't see it on Vans site or ACS.
Silly me to think the gum balls would actually come in the gum ball machine
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Kelly McMullen
Joined: 16 Apr 2008 Posts: 1188 Location: Sun Lakes AZ
|
Posted: Thu Jan 20, 2011 6:43 am Post subject: voltage regulators/alternator |
|
|
http://www.plane-power.com/R1224.htm
http://www.plane-power.com/dealers.htm
http://www.aircraftspruce.com/catalog/eppages/planePowerSAL.php
http://www.chiefaircraft.com/airsec/Aircraft/ElectricalSystem/Alternators.html
Airpower has it as well for $150, Chief 155 and the rest of the dealers shown seem to want $168.
On Thu, Jan 20, 2011 at 7:04 AM, John Gonzalez <indigoonlatigo(at)msn.com (indigoonlatigo(at)msn.com)> wrote:
Quote: | I thought I was going to mount my alternator this weekend and finish everything up. Again no instruction in the box for the Plane Power alternator, so I looked online and found the installation instructions.
WHere do I purchase the R1224 regulator? I didn't see it on Vans site or ACS.
Silly me to think the gum balls would actually come in the gum ball machine.
John
Quote: |
get="_blank">http://www.matronics.com/Navigator?RV10-List
tp://forums.matronics.com
_blank">http://www.matronics.com/contribution
|
|
#avg_ls_inline_popup{position: absolute;z-index: 9999;padding: 0px 0px;margin-left: 0px;margin-top: 0px;overflow: hidden;word-wrap: break-word;color: black;font-size: 10px;text-align: left;line-height: 130%;} [quote][b]
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ Kelly McMullen
A&P/IA, EAA Tech Counselor
KCHD |
|
Back to top |
|
 |
Tim Olson
Joined: 25 Jan 2007 Posts: 2879
|
Posted: Thu Jan 20, 2011 6:44 am Post subject: voltage regulators/alternator |
|
|
What alternator did you get that requires a regulator? Most
of the plane-Power's that people are using are coming
with the built-in regulator and there's very little that
needs to be wired.
Tim Olson - RV-10 N104CD
do not archive
On 1/20/2011 8:04 AM, John Gonzalez wrote:
Quote: | I thought I was going to mount my alternator this weekend and finish
everything up. Again no instruction in the box for the Plane Power
alternator, so I looked online and found the installation instructions.
WHere do I purchase the R1224 regulator? I didn't see it on Vans site or
ACS.
Silly me to think the gum balls would actually come in the gum ball machine.
John
*
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Kelly McMullen
Joined: 16 Apr 2008 Posts: 1188 Location: Sun Lakes AZ
|
Posted: Thu Jan 20, 2011 7:07 am Post subject: voltage regulators/alternator |
|
|
Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
On Thu, Jan 20, 2011 at 7:41 AM, Tim Olson <Tim(at)myrv10.com (Tim(at)myrv10.com)> wrote:
Quote: | --> RV10-List message posted by: Tim Olson <Tim(at)myrv10.com (Tim(at)myrv10.com)>
What alternator did you get that requires a regulator? Most
of the plane-Power's that people are using are coming
with the built-in regulator and there's very little that
needs to be wired.
Tim Olson - RV-10 N104CD
do not archive
On 1/20/2011 8:04 AM, John Gonzalez wrote:
Quote: | I thought I was going to mount my alternator this weekend and finish
everything up. Again no instruction in the box for the Plane Power
alternator, so I looked online and found the installation instructions.
WHere do I purchase the R1224 regulator? I didn't see it on Vans site or
ACS.
Silly me to think the gum balls would actually come in the gum ball machine.
John
*
|
===========
arget="_blank">http://www.matronics.com/Navigator?RV10-List
===========
http://forums.matronics.com
===========
le, List Admin.
="_blank">http://www.matronics.com/contribution
===========
|
#avg_ls_inline_popup{position: absolute;z-index: 9999;padding: 0px 0px;margin-left: 0px;margin-top: 0px;overflow: hidden;word-wrap: break-word;color: black;font-size: 10px;text-align: left;line-height: 130%;} [quote][b]
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ Kelly McMullen
A&P/IA, EAA Tech Counselor
KCHD |
|
Back to top |
|
 |
Kellym
Joined: 10 Jan 2006 Posts: 1705 Location: Sun Lakes AZ
|
Posted: Thu Jan 20, 2011 7:16 am Post subject: voltage regulators/alternator |
|
|
OTOH, Tim maybe correct. Verify which model you have from Plane Power to
see whether it needs external regulator, or if it already has one
built-in. I sorta recall Van's favoring the internally regulated versions.
On 1/20/2011 8:02 AM, Kelly McMullen wrote:
Quote: | Plane power sells both varieties. Opinions vary about the merits of
built-in regulators in an aircraft setting where it is desirable to be
able to turn off all alternator output. Depends on your outlook as to
who will be fixing any electrical problems after a failure, given that
most A&Ps are only familiar with externally regulated alternators that
exist on certified planes. The point being internal vs external
alternator regulation is to the AeroElectric email list what primer
debates are to most OBAM lists like this one.
On Thu, Jan 20, 2011 at 7:41 AM, Tim Olson <Tim(at)myrv10.com
<mailto:Tim(at)myrv10.com>> wrote:
<mailto:Tim(at)myrv10.com>>
What alternator did you get that requires a regulator? Most
of the plane-Power's that people are using are coming
with the built-in regulator and there's very little that
needs to be wired.
Tim Olson - RV-10 N104CD
do not archive
On 1/20/2011 8:04 AM, John Gonzalez wrote:
I thought I was going to mount my alternator this weekend and
finish
everything up. Again no instruction in the box for the Plane Power
alternator, so I looked online and found the installation
instructions.
WHere do I purchase the R1224 regulator? I didn't see it on
Vans site or
ACS.
Silly me to think the gum balls would actually come in the gum
ball machine.
John
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ Kelly McMullen
A&P/IA, EAA Tech Counselor # 5286
KCHD |
|
Back to top |
|
 |
pilotdds(at)aol.com Guest
|
Posted: Thu Jan 20, 2011 7:53 am Post subject: voltage regulators/alternator |
|
|
The plane power alternator that vans sells is internally regulated and has built in over voltage protection-much simpler wiring,so John, relax.
--
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Strasnuts
Joined: 10 Feb 2009 Posts: 502 Location: Salt Lake City, UT
|
Posted: Thu Jan 20, 2011 7:54 am Post subject: voltage regulators/alternator |
|
|
My planepower from vans has the internal regulator.
Sent from my iPhone
On Jan 20, 2011, at 8:14, Kelly McMullen <kellym(at)aviating.com> wrote:
Quote: |
OTOH, Tim maybe correct. Verify which model you have from Plane Power to see whether it needs external regulator, or if it already has one built-in. I sorta recall Van's favoring the internally regulated versions.
On 1/20/2011 8:02 AM, Kelly McMullen wrote:
> Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
>
> On Thu, Jan 20, 2011 at 7:41 AM, Tim Olson <Tim(at)myrv10.com <mailto:Tim(at)myrv10.com>> wrote:
>
>
> <mailto:Tim(at)myrv10.com>>
>
> What alternator did you get that requires a regulator? Most
> of the plane-Power's that people are using are coming
> with the built-in regulator and there's very little that
> needs to be wired.
>
>
> Tim Olson - RV-10 N104CD
> do not archive
>
>
>
> On 1/20/2011 8:04 AM, John Gonzalez wrote:
>
> I thought I was going to mount my alternator this weekend and
> finish
> everything up. Again no instruction in the box for the Plane Power
> alternator, so I looked online and found the installation
> instructions.
>
> WHere do I purchase the R1224 regulator? I didn't see it on
> Vans site or
> ACS.
>
> Silly me to think the gum balls would actually come in the gum
> ball machine.
>
> John
>
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ 40936
RV-10 SB N801VR Flying
780 Hours
SuperSTOL 60 hours |
|
Back to top |
|
 |
jesse(at)saintaviation.co Guest
|
Posted: Thu Jan 20, 2011 8:37 am Post subject: voltage regulators/alternator |
|
|
You can turn off the Alt Field on the internally regulated alternator just like you would from an externally regulated one, right? If the alternator or regulator fails, you replace it or send it in for repair, or have someone locally repair it if there are still people around that do that. Oh, btw, I use the Akzo Nobel 2-part epoxy primer on all internal parts.
do not archive
Jesse Saint
Saint Aviation, Inc.
jesse(at)saintaviation.com
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 10:02 AM, Kelly McMullen wrote:
Quote: | Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
indigoonlatigo(at)msn.com Guest
|
Posted: Thu Jan 20, 2011 9:07 am Post subject: voltage regulators/alternator |
|
|
I am cementing PJC crowns 23-27 and veneer of 22....relax...sho are you kiddding!!!!
Not at home to look at the box, but I do know the alternator has a built in over voltage protection.
To: rv10-list(at)matronics.com
Subject: Re: voltage regulators/alternator
From: pilotdds(at)aol.com
Date: Thu, 20 Jan 2011 10:47:49 -0500
The plane power alternator that vans sells is internally regulated and has built in over voltage protection-much simpler wiring,so John, relax.
--
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
dlm34077(at)q.com Guest
|
Posted: Thu Jan 20, 2011 9:09 am Post subject: voltage regulators/alternator |
|
|
yes, I just turn off the W31 5A breaker to shut off the alternator output.
Replacing the integrated diodes,regulator and brushes is a single field
installed part ; cost me about $50. But of course did not solve the problem
in my case.
---
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Tim Olson
Joined: 25 Jan 2007 Posts: 2879
|
Posted: Thu Jan 20, 2011 9:23 am Post subject: voltage regulators/alternator |
|
|
If it has built-in OVP, then it's internally regulated. In that
case you don't need a regulator. I understand Kelly's
original statement from that perspective. I was just
basically operating under the understanding that most people
building RV-10's that have Plane-power alternators from Van's,
were getting internally regulated and OVP'd alternators,
and if that were true, you shouldn't have a need to buy
a regulator. The wiring is also dead simple.
The one gotcha I can add....before I did my first flight,
I thought I had an alternator problem. Turns out I didn't
push hard enough on the connector on the rear of the
alternator to click in the connector, and it had come
loose. So, when you connect that connector, make sure you
push it in until you get a definite click.
Tim Olson - RV-10 N104CD
do not archive
On 1/20/2011 11:04 AM, John Gonzalez wrote:
[quote] I am cementing PJC crowns 23-27 and veneer of 22....relax...sho are you
kiddding!!!!
Not at home to look at the box, but I do know the alternator has a built
in over voltage protection.
------------------------------------------------------------------------
To: rv10-list(at)matronics.com
Subject: Re: voltage regulators/alternator
From: pilotdds(at)aol.com
Date: Thu, 20 Jan 2011 10:47:49 -0500
The plane power alternator that vans sells is internally regulated and
has built in over voltage protection-much simpler wiring,so John, relax.
--
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Kelly McMullen
Joined: 16 Apr 2008 Posts: 1188 Location: Sun Lakes AZ
|
Posted: Thu Jan 20, 2011 4:17 pm Post subject: voltage regulators/alternator |
|
|
Not on all of them Jesse. Might be okay on Plane Power, don't know for sure. The automotive ones are NOT designed to allow field to be turned off while there is a load on the alternator, and can be substantially damaged by doing so.
There is no such issue or concern on externally regulated, and gives you option of which regulator goes with your choice of primer.
On Thu, Jan 20, 2011 at 9:26 AM, Jesse Saint <jesse(at)saintaviation.com (jesse(at)saintaviation.com)> wrote:
Quote: | --> RV10-List message posted by: Jesse Saint <jesse(at)saintaviation.com (jesse(at)saintaviation.com)>
You can turn off the Alt Field on the internally regulated alternator just like you would from an externally regulated one, right? If the alternator or regulator fails, you replace it or send it in for repair, or have someone locally repair it if there are still people around that do that. Oh, btw, I use the Akzo Nobel 2-part epoxy primer on all internal parts.
do not archive
Jesse Saint
Saint Aviation, Inc.
jesse(at)saintaviation.com (jesse(at)saintaviation.com)
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 10:02 AM, Kelly McMullen wrote:
> Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
========================
arget="_blank">http://www.matronics.com/Navigator?RV10-List
===========
http://forums.matronics.com
===========
le, List Admin.
="_blank">http://www.matronics.com/contribution
===========
|
#avg_ls_inline_popup{position: absolute;z-index: 9999;padding: 0px 0px;margin-left: 0px;margin-top: 0px;overflow: hidden;word-wrap: break-word;color: black;font-size: 10px;text-align: left;line-height: 130%;} [quote][b]
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ Kelly McMullen
A&P/IA, EAA Tech Counselor
KCHD |
|
Back to top |
|
 |
jesse(at)saintaviation.co Guest
|
Posted: Thu Jan 20, 2011 4:47 pm Post subject: voltage regulators/alternator |
|
|
I wonder if that's why Van's dropped the automotive alternators from the FWF kit and started using the Plane Power. If you asked them about the earlier alternator, though, they would likely say that they have not heard from any customers about problems with them.
Jesse Saint
Saint Aviation, Inc.
jesse(at)saintaviation.com (jesse(at)saintaviation.com)
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 7:14 PM, Kelly McMullen wrote:
[quote]Not on all of them Jesse. Might be okay on Plane Power, don't know for sure. The automotive ones are NOT designed to allow field to be turned off while there is a load on the alternator, and can be substantially damaged by doing so.
There is no such issue or concern on externally regulated, and gives you option of which regulator goes with your choice of primer.
On Thu, Jan 20, 2011 at 9:26 AM, Jesse Saint <jesse(at)saintaviation.com (jesse(at)saintaviation.com)> wrote:
Quote: | --> RV10-List message posted by: Jesse Saint <jesse(at)saintaviation.com (jesse(at)saintaviation.com)>
You can turn off the Alt Field on the internally regulated alternator just like you would from an externally regulated one, right? If the alternator or regulator fails, you replace it or send it in for repair, or have someone locally repair it if there are still people around that do that. Oh, btw, I use the Akzo Nobel 2-part epoxy primer on all internal parts.
do not archive
Jesse Saint
Saint Aviation, Inc.
jesse(at)saintaviation.com (jesse(at)saintaviation.com)
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 10:02 AM, Kelly McMullen wrote:
> Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
========================
arget="_blank">http://www.matronics.com/Navigator?RV10-List
===========
http://forums.matronics.com
===========
le, List Admin.
="_blank">http://www.matronics.com/contribution
===========
|
#avg_ls_inline_popup{position: absolute;z-index: 9999;padding: 0px 0px;margin-left: 0px;margin-top: 0px;overflow: hidden;word-wrap: break-word;color: black;font-size: 10px;text-align: left;line-height: 130%;} [b]
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
jump2(at)sbcglobal.net Guest
|
Posted: Thu Jan 20, 2011 5:35 pm Post subject: voltage regulators/alternator |
|
|
Mine went out at 67 hrs, bought a plane power and have not looked back. Yes, it did say not to turn the alternator off-on with a load on it. I believe it was in vans info.
Patrick Thyssen
N15PT
--- On Thu, 1/20/11, Jesse Saint <jesse(at)saintaviation.com> wrote:
Quote: |
From: Jesse Saint <jesse(at)saintaviation.com>
Subject: Re: voltage regulators/alternator
To: rv10-list(at)matronics.com
Date: Thursday, January 20, 2011, 6:45 PM
I wonder if that's why Van's dropped the automotive alternators from the FWF kit and started using the Plane Power. If you asked them about the earlier alternator, though, they would likely say that they have not heard from any customers about problems with them.
Jesse Saint
Saint Aviation, Inc.
[url=/mc/compose?to=jesse(at)saintaviation.com]jesse(at)saintaviation.com[/url]
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 7:14 PM, Kelly McMullen wrote:
Quote: | Not on all of them Jesse. Might be okay on Plane Power, don't know for sure. The automotive ones are NOT designed to allow field to be turned off while there is a load on the alternator, and can be substantially damaged by doing so.
There is no such issue or concern on externally regulated, and gives you option of which regulator goes with your choice of primer.
On Thu, Jan 20, 2011 at 9:26 AM, Jesse Saint <[url=/mc/compose?to=jesse(at)saintaviation.com]jesse(at)saintaviation.com[/url]> wrote:
Quote: | --> RV10-List message posted by: Jesse Saint <[url=/mc/compose?to=jesse(at)saintaviation.com]jesse(at)saintaviation.com[/url]>
You can turn off the Alt Field on the internally regulated alternator just like you would from an externally regulated one, right? If the alternator or regulator fails, you replace it or send it in for repair, or have someone locally repair it if there are still people around that do that. Oh, btw, I use the Akzo Nobel 2-part epoxy primer on all internal parts.
do not archive
Jesse Saint
Saint Aviation, Inc.
[url=/mc/compose?to=jesse(at)saintaviation.com]jesse(at)saintaviation.com[/url]
C: 352-427-0285
F: 815-377-3694
On Jan 20, 2011, at 10:02 AM, Kelly McMullen wrote:
> Plane power sells both varieties. Opinions vary about the merits of built-in regulators in an aircraft setting where it is desirable to be able to turn off all alternator output. Depends on your outlook as to who will be fixing any electrical problems after a failure, given that most A&Ps are only familiar with externally regulated alternators that exist on certified planes. The point being internal vs external alternator regulation is to the AeroElectric email list what primer debates are to most OBAM lists like this one.
========================
arget="_blank">http://www.matronics.com/Navigator?RV10-List
===========
http://forums.matronics.com
===========
le, List Admin.
="_blank">http://www.matronics.com/contribution
===========
|
#yiv453473072 #yiv453473072avg_ls_inline_popup{padding:0px 0px;margin-left:0px;margin-top:0px;overflow:hidden;word-wrap:break-word;color:black;font-size:10px;text-align:left;line-height:130%;} D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D |
| [quote][b]
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
Kellym
Joined: 10 Jan 2006 Posts: 1705 Location: Sun Lakes AZ
|
Posted: Thu Jan 20, 2011 6:14 pm Post subject: voltage regulators/alternator |
|
|
Is there any other script in the tech support room?
On 1/20/2011 5:45 PM, Jesse Saint wrote:
Quote: | ** If you asked them about the earlier alternator, though, they would
likely say that they have not heard from any customers about problems
with them.
Jesse Saint
Saint Aviation, Inc.
jesse(at)saintaviation.com <mailto:jesse(at)saintaviation.com>
C: 352-427-0285
F: 815-377-3694
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
_________________ Kelly McMullen
A&P/IA, EAA Tech Counselor # 5286
KCHD |
|
Back to top |
|
 |
Tim Olson
Joined: 25 Jan 2007 Posts: 2879
|
Posted: Thu Jan 20, 2011 6:25 pm Post subject: voltage regulators/alternator |
|
|
"Just build the plane!"
Tim
On Jan 20, 2011, at 8:11 PM, Kelly McMullen <kellym(at)aviating.com> wrote:
Quote: |
Is there any other script in the tech support room?
On 1/20/2011 5:45 PM, Jesse Saint wrote:
> ** If you asked them about the earlier alternator, though, they would likely say that they have not heard from any customers about problems with them.
>
> Jesse Saint
> Saint Aviation, Inc.
> jesse(at)saintaviation.com <mailto:jesse(at)saintaviation.com>
> C: 352-427-0285
> F: 815-377-3694
|
| - The Matronics RV10-List Email Forum - | | Use the List Feature Navigator to browse the many List utilities available such as the Email Subscriptions page, Archive Search & Download, 7-Day Browse, Chat, FAQ, Photoshare, and much more:
http://www.matronics.com/Navigator?RV10-List |
|
|
|
Back to top |
|
 |
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum You cannot attach files in this forum You can download files in this forum
|
Powered by phpBB © 2001, 2005 phpBB Group
|